A bioresorbable everolimus-eluting scaff old versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II)...

A bioresorbable everolimus-eluting scaff old versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II)...

  • 分类:学术论文
  • 作者:
  • 来源:
  • 发布时间:2016-08-12 09:23
  • 访问量:

【概要描述】Background Despite rapid dissemination of an everolimus-eluting bioresorbable scaffold for treatment for coronary artery disease, no data from comparisons with its metallic stent counterpart are available. In a randomised controlled trial we aimed to compare an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent. Here we report secondary clinical and procedural outcomes after 1 year of follow-up.

A bioresorbable everolimus-eluting scaff old versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions (ABSORB II)...

【概要描述】Background Despite rapid dissemination of an everolimus-eluting bioresorbable scaffold for treatment for coronary artery disease, no data from comparisons with its metallic stent counterpart are available. In a randomised controlled trial we aimed to compare an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent. Here we report secondary clinical and procedural outcomes after 1 year of follow-up.

  • 分类:学术论文
  • 作者:
  • 来源:
  • 发布时间:2016-08-12 09:23
  • 访问量:
详情

  Background Despite rapid dissemination of an everolimus-eluting bioresorbable scaffold for treatment for coronary artery disease, no data from comparisons with its metallic stent counterpart are available. In a randomised controlled trial we aimed to compare an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent. Here we report secondary clinical and procedural outcomes after 1 year of follow-up.

  Methods In a single-blind, multicentre, randomised trial, we enrolled eligible patients aged 18–85 years with evidence of myocardial ischaemia and one or two de-novo native lesions in different epicardial vessels. We randomly assigned patients in a 2:1 ratio to receive treatment with an everolimus-eluting bioresorbable scaffold (Absorb, Abbott Vascular, Santa Clara, CA, USA) or treatment with an everolimus-eluting metallic stent (Xience, Abbott Vascular, Santa Clara, CA, USA). Randomisation was stratified by diabetes status and number of planned target lesions. The co-primary endpoints of this study are vasomotion (change in mean lumen diameter before and after nitrate administration at 3 years) and difference between minimum lumen diameter (after nitrate administration) after the index procedure and at 3 years. Secondary endpoints were procedural performance assessed by quantitative angiography and intravascular ultrasound; composite clinical endpoints based on death, myocardial infarction, and coronary revascularisation; device and procedural success; and angina status assessed by the Seattle Angina Questionnaire and exercise testing at 6 and 12 months. Cumulative angina rate based on adverse event reporting was analysed post hoc. This trial is registered at ClinicalTrials.gov, number NCT01425281.

  Findings Between Nov 28, 2011, and June 4, 2013, we enrolled 501 patients and randomly assigned them to the bioresorbable scaffold group (335 patients, 364 lesions) or the metallic stent group (166 patients, 182 lesions). Dilatation pressure and balloon diameter at the highest pressure during implantation or postdilatation were higher and larger in the metallic stent group, whereas the acute recoil post implantation was similar (0.19 mm for both, p=0.85). Acute lumen gain was lower for the bioresorbable scaffold by quantitative coronary angiography (1.15 mm vs 1.46 mm, p<0·0001) and quantitative intravascular ultrasound (2.85 mm2 vs 3.60 mm2, p<0·0001), resulting in a smaller lumen diameter or area post procedure. At 1 year, however, cumulative rates of first new or worsening angina from adverse event reporting were lower (72 patients [22%] in the bioresorbable scaffold group vs 50 [30%] in the metallic stent group, p=0·04), whereas performance during maximum exercise and angina status by SAQ were similar. The 1-year composite device orientated endpoint was similar between the bioresorbable scaffold and metallic stent groups (16 patients [5%] vs five patients [3%], p=0.35). Three patients in the bioresorbable scaffold group had definite or probable scaffold thromboses (one definite acute, one definite sub-acute, and one probable late), compared with no patients in the metallic stent group. There were 17 (5%) major cardiac adverse events in the bioresorbable scaffold group compared with five (3%) events in the metallic stent group, with the most common adverse events being myocardial infarction (15 cases [4%] vs two cases [1%], respectively) and clinically indicated target-lesion revascularisation (four cases [1%] vs three cases [2%], respectively).

  Interpretation The everolimus-eluting bioresorbable scaff old showed similar 1-year composite secondary clinical outcomes to the everolimus-eluting metallic stent.

阿迈特“易泊EZPo?”支架定位系统在河南省胸科医院成功完成上市后临床应用
2023 08-12

阿迈特“易泊EZPo?”支架定位系统在河南省胸科医院成功完成上市后临床应用

北京阿迈特的颅内球囊扩张导管产品获批上市
2023 08-10

北京阿迈特的颅内球囊扩张导管产品获批上市

喜报—北京阿迈特医疗器械有限公司取得国医械华光认证GB/T 42061-2022 idt ISO13485:2016医疗器械质量管理体系认证证书
2023 07-21

喜报—北京阿迈特医疗器械有限公司取得国医械华光认证GB/T 42061-2022 idt ISO13485:2016医疗器械质量管理体系认证证书

公司信息

北京阿迈特医疗器械有限公司

Beijing Advanced Medical Technologies,Ltd.Inc.

联系我们

地址:北京市大兴区永旺西路26号院中关村医疗器械园11号楼

电话:010-6297-7955             邮箱:amt@ametcorp.com

联系我们

地址:北京市大兴区永旺西路26号院中关村医疗器械园11号楼

电话:010-6297-7955             

邮箱:amt@ametcorp.com

久久99精品国产自在现线小黄鸭,亚洲国产精品一区二区玖玖爱,亚洲日韩精品无码av海量国产精,日产精品久久久1区2区_影院 久久久久久久久亚洲精品_久久久一区二区人妻av_国产午夜影院黄色片_日韩一区二区在线视频 精品久久久久久久中文字幕|十八禁无码免费网站|A片免费一级无码|人妻被按摩到潮喷中文字幕 色欲天天_久久精彩_精品日本一区二区三区在线观看_精品久久久久无码人妻中文字幕 欧美性战a久久久久久_91精品无码一区_欧美oumeisetu_久久国产乱子伦精 久久久午夜视频,久久国产第一区二区三区日韩精品,欧美综合精品激情久久久久,国内精品一区二区